Contact us here
Controls

DPA

The DPA is an easy-to-use desk panel for adjusting lifting columns in adjustable workstations or office desks. Simple, durable, and made to match almost any desk design.

DPA

The DPA desk panel is a small, compact and user-friendly panel, which can be used for all kinds of height adjustable desks from heavy-duty workstations to standard office desks. 

The raised up and down buttons shaped as arrowheads make the panel very intuitive to use. The panel front is adjustable making it very flexible to be mounted in different ways thereby blending perfectly into any desk design.

Got a question?

Our team is ready to assist you with technical information, starting a project and more.

Contact now
DPA data sheet

View the data sheet as an online magazine or download the PDF.

DB5/DB6 with CBD4/CBD5/CBD6 user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL1A with CBD4/CBD5/CBD6 user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL2/LC1 with CBD6S user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL2 with CBD4/CBD5/CBD6 user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL4S with CBD6S user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL5/DL6 with CBD4/CBD5/CBD6 user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL7 with CBD4/CBD5/CBD6 user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL8/DL9/DL10/DL11 with CBD6S user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL8/DL9/DL10/DL11 with CBD4/CBD5/CBD6 user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL12/DL14/DB14/DL17 with CBD6S user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL12/DL14/DB14/DL17 with CBD4/CBD5/CBD6 user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL15/DL16 with CBD6S user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

DL15/DL16 with CBD4/CBD5/CBD6 user manual

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

Controls and handsets user manuals

This user manual will tell you how to install, use and maintain your LINAK DESKLINE products.

Focus on shop interiors

Propelled by LINAK electric actuators, height adjustable counters allow all members of staff to pick a position that is right for them, anytime of the day, whatever the task.

Focus on display and monitor stands

Improve communication by adding electric movement to display and monitor stands - bringing your message at eye-level to the end-user.

DESKLINE product overview

If you make any kind of desk, table or counter that people work behind, a height adjustable electric actuator solution is the flexible way to gain a competitive edge and improve your business.

DESKLINE quality matters

We use high quality components, state-of-the art production and the most demanding testing standards in the industry to achieve excellent quality.

How to clean your desk panel

Watch and learn how to easily clean your LINAK desk panel/switch in this short instruction video: How to clean it; which cleaning agents to use; and, last but not least, what you need to pay attention to.

Clean your desk panel with a soft damp cloth. Universal cleaning detergents may be used.

To disinfect the desk panel, use a 70% isopropyl alcohol either as a wipe or add a small amount to a soft cloth.

Warnings
The desk panel is not a sealed unit and there are electronics inside it. If liquids or moisture get into an opening, the PCB may be damaged, and the desk panel ruined.

So:

  • Avoid moisture penetrating any openings as this may damage the PCB inside the desk panel
  • Avoid spraying the cleaning agent or disinfectant directly on the desk panel as moisture may penetrate openings, damaging the PCB inside the desk panel
  • Cleaning agents and disinfectants must not be highly alkaline or acidic (pH value must be 6 to 8), and they must not contain bleach or chlorine
  • Do not use hand sanitiser gel as a cleaning agent

Alkaline and acidic cleaning agents may, over time, decompose the housing. Hand sanitiser gel may deposit on the desk panel buttons. Over time, the buttons may get stuck, or they may not work properly.

All desk panels – How to initialise your desk

The desk cannot be raised if it has not been initialised.

If error code 'E01' is shown in the display, the desk must be initialised.

How to initialise your desk:

  1. Press the down key until the desk is lowered completely. Hold the key until the desk no longer moves.
  2. Reactivate the down key and hold until the desk no longer moves.

Now the desk can be raised.

The desk can only be lowered

The desk needs to be initialised.

Follow the procedure shown in the video.

The desk cannot be raised or lowered

Possible problem: Mains not connected to the control box
Try/Solution: Try to connect a lamp or similar to the mains supply to check whether there is adequate supply voltage. 

Possible problem: Are plugs mounted correctly in the control box or to the leg?
Try/Solution: Check all connections. 

Possible problem: Are there any visible damages on cables, controls, the control box or legs?
Try/Solution: Damaged parts must be exchanged. Contact the company that sold you the desk. 

The desk cannot be raised full stroke. Always stops in same position.

The system has set a new end-stop outwards.

To reset a saved position, the desk must be re-initialised. Follow the procedure shown in the video.

Got a question?

Our team is ready to assist you with technical information, starting a project and more.

Contact now

LINAK News

Stay up to date on linear actuator technology

Subscribe